Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Author index

Page Path
HOME > Browse articles > Author index
Search
Daniel Guimarães Pedro Rocha 2 Articles
In vivo assessment of accuracy of Propex II, Root ZX II, and radiographic measurements for location of the major foramen
Fernanda Garcia Tampelini, Marcelo Santos Coelho, Marcos de Azevêdo Rios, Carlos Eduardo Fontana, Daniel Guimarães Pedro Rocha, Sergio Luiz Pinheiro, Carlos Eduardo da Silveira Bueno
Restor Dent Endod 2017;42(3):200-205.   Published online May 16, 2017
DOI: https://doi.org/10.5395/rde.2017.42.3.200
AbstractAbstract PDF
Objectives

The aim of this in vivo study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF).

Materials and Methods

Thirty-two premolars with single canals that required extraction were included. Following anesthesia, access, and initial canal preparation with size 10 and 15 K-flex files and SX and S1 rotary ProTaper files, the canals were irrigated with 2.5% sodium hypochlorite. The length of the root canal was verified 3 times for each tooth using the 2 apex locators and once using the radiographic technique. Teeth were extracted and the actual WL was determined using size 15 K-files under a × 25 magnification. The Biostat 4.0 program (AnalystSoft Inc.) was used for comparing the direct measurements with those obtained using radiographic technique and the apex locators. Pearson's correlation analysis and analysis of variance (ANOVA) were used for statistical analyses.

Results

The measurements obtained using the visual method exhibited the strongest correlation with Root ZX II (r = 0.94), followed by Propex II (r = 0.90) and Ingle's technique (r = 0.81; p < 0.001). Descriptive statistics using ANOVA (Tukey's post hoc test) revealed significant differences between the radiographic measurements and both EALs measurements (p < 0.05).

Conclusions

Both EALs presented similar accuracy that was higher than that of the radiographic measurements obtained with Ingle's technique. Our results suggest that the use of these EALs for MF location is more accurate than the use of radiographic measurements.

Citations

Citations to this article as recorded by  
  • How Do Different Image Modules Impact the Accuracy of Working Length Measurements in Digital Periapical Radiography? An In Vitro Study
    Vahide Hazal Abat, Rabia Figen Kaptan
    Diagnostics.2025; 15(3): 305.     CrossRef
  • Influence of maintaining apical patency in post-endodontic pain
    Snigdha Shubham, Manisha Nepal, Ravish Mishra, Kishor Dutta
    BMC Oral Health.2021;[Epub]     CrossRef
  • 3,071 View
  • 11 Download
  • 2 Crossref
Close layer
Interplay between surface characteristics, instrument design, and mechanical behavior of contemporary heat-treated nickel-titanium instruments: an in vitro comparative study
Tânia Nunes Soares, Emmanuel João Nogueira Leal da Silva, Carlos Nelson Elias, Daniel Guimarães Pedro Rocha, Victor Talarico Leal Vieira
J Korean Acad Conserv Dent ;Published online October 29, 2026
DOI: https://doi.org/10.5395/rde.2027.52.e1
AbstractAbstract
Objectives
This study aimed to evaluate the surface characteristics and mechanical behavior of contemporary thermally treated nickel-titanium (NiTi) rotary instruments, focusing on the interplay between surface condition, instrument design, and mechanical performance.
Methods
A total of 180 instruments were included (n = 45 per group): TruNatomy Prime (TRN; 26/.04), ProTaper Next X2 (PTN; 25/.06), ProTaper Gold F2 (PTG; 25/.08), and ProTaper Ultimate F2 (PTU; 25/.08). Surface characteristics were assessed qualitatively using scanning electron microscopy and quantitatively by optical profilometry. Mechanical properties, including bending, buckling, cyclic fatigue, and torsional resistance, were evaluated using standardized testing methods. Data were analyzed using one-way ANOVA and the Student-Newman-Keuls post hoc test (α = 0.05).
Results
PTN exhibited significantly higher surface roughness compared to the other systems (p < 0.05). Flexibility was greatest for TRN and lowest for PTN (p < 0.05), whereas buckling resistance and maximum torque were highest for PTG (p < 0.05). Cyclic fatigue resistance was similar among TRN, PTG, and PTU, all outperforming PTN (p < 0.05). Despite marked differences in alloy and design, PTN and TRN showed comparable torsional resistance (p > 0.05). Angular deflection was highest for TRN and lowest for PTN (p < 0.05).
Conclusions
The mechanical behavior of thermally treated NiTi instruments is multifactorial and cannot be explained by alloy type or design alone. Instead, performance reflects the interaction between surface characteristics, geometry, and metallurgical properties. These findings highlight the importance of a comprehensive approach to instrument selection based on the specific mechanical demands of each clinical scenario.
  • 0 View
  • 0 Download
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP