Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Search

Page Path
HOME > Search
1 "Larissa Pereira Lagos de Melo"
Filter
Filter
Article category
Keywords
Publication year
Authors
  • rupiahtoto
  • rupiahtoto
  • rupiahtoto
  • rupiahtoto
  • rupiahtoto
  • rupiahtoto
  • slot deposit pulsa
  • bo slot gacor
  • toto togel
  • slot gacor
  • login rupiahtoto
  • rupiahtoto
  • rupiahtoto
  • rupiahtoto
  • Research Article
    Influence of CBCT parameters on image quality and the diagnosis of vertical root fractures in teeth with metallic posts: an ex vivo study
    Larissa Pereira Lagos de Melo, Polyane Mazucatto Queiroz, Larissa Moreira-Souza, Mariana Rocha Nadaes, Gustavo Machado Santaella, Matheus Lima Oliveira, Deborah Queiroz Freitas
    Restor Dent Endod 2023;48(2):e16.   Published online April 27, 2023
    DOI: https://doi.org/10.5395/rde.2023.48.e16
    AbstractAbstract PDFPubReaderePub
    Objectives

    The aim of this study was to evaluate the influence of peak kilovoltage (kVp) and a metal artifact reduction (MAR) tool on image quality and the diagnosis of vertical root fracture (VRF) in cone-beam computed tomography (CBCT).

    Materials and Methods

    Twenty single-rooted human teeth filled with an intracanal metal post were divided into 2 groups: control (n = 10) and VRF (n = 10). Each tooth was placed into the socket of a dry mandible, and CBCT scans were acquired using a Picasso Trio varying the kVp (70, 80, 90, or 99), and the use of MAR (with or without). The examinations were assessed by 5 examiners for the diagnosis of VRF using a 5-point scale. A subjective evaluation of the expression of artifacts was done by comparing random axial images of the studied protocols. The results of the diagnoses were analyzed using 2-way analysis of variance and the Tukey post hoc test, the subjective evaluations were compared using the Friedman test, and intra-examiner reproducibility was evaluated using the weighted kappa test (α = 5%).

    Results

    The kVp and MAR did not influence the diagnosis of VRF (p > 0.05). According to the subjective classification, the 99 kVp protocol with MAR demonstrated the least expression of artifacts, while the 70 kVp protocol without MAR led to the most artifacts.

    Conclusions

    Protocols with higher kVp combined with MAR improved the image quality of CBCT examinations. However, those factors did not lead to an improvement in the diagnosis of VRF.

    Citations

    Citations to this article as recorded by  
    • Diagnostic Performance of Iterative Reconstruction of Cone-beam Computed Tomography for Detecting Vertical Root Fractures in the Presence of Metal Artifacts
      Matheus Barros-Costa, Gustavo Santaella, Christiano Oliveira-Santos, Deborah Queiroz Freitas, William C. Scarfe, Francisco Carlos Groppo
      Journal of Endodontics.2025;[Epub]     CrossRef
    • Radiographic and Clinical Outcomes of Laser-Enhanced Disinfection in Endodontic Therapy
      Janos Kantor, Sorana Maria Bucur, Eugen Silviu Bud, Victor Nimigean, Ioana Maria Crișan, Mariana Păcurar
      Journal of Clinical Medicine.2025; 14(12): 4055.     CrossRef
    • Vertical root fracture diagnosis in teeth with metallic posts: Impact of metal artifact reduction and sharpening filters
      Débora Costa Ruiz, Lucas P. Lopes Rosado, Rocharles Cavalcante Fontenele, Amanda Farias-Gomes, Deborah Queiroz Freitas
      Imaging Science in Dentistry.2024; 54(2): 139.     CrossRef
    • Comparing standard- and low-dose CBCT in diagnosis and treatment decisions for impacted mandibular third molars: a non-inferiority randomised clinical study
      Kuo Feng Hung, Andy Wai Kan Yeung, May Chun Mei Wong, Michael M. Bornstein, Yiu Yan Leung
      Clinical Oral Investigations.2024;[Epub]     CrossRef
    • 632 View
    • 25 Download
    • 3 Web of Science
    • 4 Crossref
    Close layer

    Restor Dent Endod : Restorative Dentistry & Endodontics
    Close layer
    TOP