  • Original Article Development of chewing simulator
    Sung-Ho Park, Il-Young Jung, Kwon-Yong Lee#
    2003;28(1):-40.
    DOI: https://doi.org/10.5395/JKACD.2003.28.1.034
    Published online: January 31, 2003

    Department of conservative Dentistry, Yonsei University, Korea.

    #Department of mechanical engineering, Sejong University, Korea.

    Corresponding author (sunghopark@yumc.yonsei.ac.kr)

    Copyright © 2003 Korean Academy of Conservative Dentistry

    • 312 Views
    • 2 Download
    • 1 Crossref
    prev next
    • Chewing simulator, which can partly mimic the motion of chewing motion of human, has been successfully developed. The purpose of its development was to make a new machine which can anticipate the clinical results of restoration in the human teeth more accurately in vitro condition It is composed of 4 major parts; chewing part, motor part, water bath, controlling part. The controlling part control the chewing force, frequency, the temperature and running time of water. Additionally, the actual chewing force and remaining time is shown in the monitor of controlling part. At present, the chewing cycle is composed depending on the pre-published data of foreign people. Long term clinical data should be additionally collected for the simulator to mimic the clinical results more accurately.
    Fig. 1
    Chewing simulator, front view
    jkacd-28-34-g001.jpg
    Fig. 2
    Chewing simulator, front view of chamber part and position control table
    jkacd-28-34-g002.jpg
    Fig. 3
    Chewing simulator, front view of chamber part
    jkacd-28-34-g003.jpg
    Fig. 4
    Chewing simulator, side view of chamber part
    jkacd-28-34-g004.jpg
    Fig. 5
    Motor part of chewing simulator
    jkacd-28-34-g005.jpg
    Fig. 6
    Movement of CAM
    jkacd-28-34-g006.jpg
    Fig. 7
    Diagram of PWM driver movement
    jkacd-28-34-g007.jpg
    Fig. 8
    Controlling part
    jkacd-28-34-g008.jpg
    • 1. Powell JM, Phillips RW, Norman RD. In-vitro wear response of composite resin, amalgam, and enamel. J Dent Res. 1975;54: 1183-1195.ArticlePubMedPDF
    • 2. Phillips RW, Avery DR, Mehra R, Swartz ML, Mccune RJ. Observations on a composite resin for class II restorations: Three-yerr report. J Prosthet Dent. 1973;30: 891-897.PubMed
    • 3. Jaworzyn JF, Arundel PA, Cantwell JB. Posterior composite restorations:simultaneous hydrothermal cycling and wear studies in vitro. J Dent Res. 1978;57: 708.PubMed
    • 4. Delong R, Peterson R, Douglas WH. A laser profiling system for measuring wear of dental materials. J Dent Res. 1989;68: 907. Abstr 328.
    • 5. Krejci I, Reich T, Lutz F, Albertoni M. In vitro-Testverfahren zur Evaluation dentaler Restorationssysteme. Schweiz Monatsschr Zahnmed. 1990;100: 953-960.PubMed
    • 6. Rateitschak KH, Renggli HH, M hlemann HR. Parodontologie. 1978;Stuttgart: Thieme; 8-10.
    • 7. Atmaram GH, Mohammed H. Estimation of physiologic stressed with a natural tooth considering fibrous PDL structure. J Dent Res. 1981;60: 873-877.ArticlePubMedPDF
    • 8. Graber G. Gnathologie. Zahntechnik (Zur). 1981;39: 427-446.PubMed
    • 9. DeLong R, Douglas WH. Development of an artificial oral environment for testing of dental restoratives: Biaxial force and movement control. J Dent Res. 1983;62: 32-36.ArticlePubMedPDF
    • 10. Anderson PJ. Measurement of stress in mastication I. J Dent Res. 1956;35: 664-670.ArticlePubMedPDF
    • 11. Bates JF, Stafford GD, Harrison A. Masticatory function--A review of the literature II. Speed of movement of the mandibule, rate of chewing and forces developed in chewing. J Oral Rehabil. 1975;2: 349-361.PubMed
    • 12. Jemt T, Karlsson S, Hedegard B. Mandibular movement of young adults recorded by intraorally placed light emitting diodes. J Prosthet Dent. 1979;42: 669-673.PubMed
    • 13. Uhlig H. Uber die Kaukraft. Dtsch Zahnarztl Z. 1953;8: 30-45.PubMed
    • 14. Schreiber S. Ein neues Gerät zur Messung und Registrierung von Kaukräfteen. Zahnarztl Rundsch. 1957;66: 127-131.
    • 15. Kraft E. Uber die Bedeuting der Kaukraft für das Kaugeschehen. Zahnarztl Prax. 1962;13: 129-130.
    • 16. Eichner K. Messung der Krafte bei Kauvorgängen. Dtsch Zahnarztl Z. 1963;18: 915-924.
    • 17. Graf H, Grassl H, Aeberhard H-J. A method for measurement of occlusal forces in three directions. Helv Odontol Acta. 1974;35: 7-11.
    • 18. De Boever JA, McCall WD Jr, Holden S, Ash MM. Functional Occlusal force: An investigation by telemetry. J Prosthet Dent. 1978;40: 326-333.PubMed
    • 19. Helkimo E, Ingervall B. Bite force and functional state of the masticatory system in young men. Swed Dent J. 1978;2: 167-175.PubMed
    • 20. Graber , Pfondler . Die Quintessenz einer praxisbezogenen Kronen-und Brückenprothetik. 1980;Berlin: Quintessenz; 25-27.
    • 21. Gibbs CH, Mahan PE, Lundeen HC, Brehnen K, Walsh EK, Holbrook WB. Occlusal force during chewing and swallowing as measured by sound transmission. J Prosthet Dent. 1981;46: 443-449.PubMed
    • 22. Schwickerath H, Coca I. Einzelkronen aus Glaskeramic. Phillip J. 1987;4: 336-338.
    • 23. Krejci I, Lutz F. In vitro Testverfahren zur Evaluation Dentalaler Restaurationssysteme. Korrelation mit In Vivo Resultaten. Schweiz Monatsschr Zahnmed. 1990;100: 1445-1449.PubMed

    Tables & Figures

    Fig. 1
    Chewing simulator, front view
    jkacd-28-34-g001.jpg
    Fig. 2
    Chewing simulator, front view of chamber part and position control table
    jkacd-28-34-g002.jpg
    Fig. 3
    Chewing simulator, front view of chamber part
    jkacd-28-34-g003.jpg
    Fig. 4
    Chewing simulator, side view of chamber part
    jkacd-28-34-g004.jpg
    Fig. 5
    Motor part of chewing simulator
    jkacd-28-34-g005.jpg
    Fig. 6
    Movement of CAM
    jkacd-28-34-g006.jpg
    Fig. 7
    Diagram of PWM driver movement
    jkacd-28-34-g007.jpg
    Fig. 8
    Controlling part
    jkacd-28-34-g008.jpg

    REFERENCES

    • 1. Powell JM, Phillips RW, Norman RD. In-vitro wear response of composite resin, amalgam, and enamel. J Dent Res. 1975;54: 1183-1195.ArticlePubMedPDF
    • 2. Phillips RW, Avery DR, Mehra R, Swartz ML, Mccune RJ. Observations on a composite resin for class II restorations: Three-yerr report. J Prosthet Dent. 1973;30: 891-897.PubMed
    • 3. Jaworzyn JF, Arundel PA, Cantwell JB. Posterior composite restorations:simultaneous hydrothermal cycling and wear studies in vitro. J Dent Res. 1978;57: 708.PubMed
    • 4. Delong R, Peterson R, Douglas WH. A laser profiling system for measuring wear of dental materials. J Dent Res. 1989;68: 907. Abstr 328.
    • 5. Krejci I, Reich T, Lutz F, Albertoni M. In vitro-Testverfahren zur Evaluation dentaler Restorationssysteme. Schweiz Monatsschr Zahnmed. 1990;100: 953-960.PubMed
    • 6. Rateitschak KH, Renggli HH, M hlemann HR. Parodontologie. 1978;Stuttgart: Thieme; 8-10.
    • 7. Atmaram GH, Mohammed H. Estimation of physiologic stressed with a natural tooth considering fibrous PDL structure. J Dent Res. 1981;60: 873-877.ArticlePubMedPDF
    • 8. Graber G. Gnathologie. Zahntechnik (Zur). 1981;39: 427-446.PubMed
    • 9. DeLong R, Douglas WH. Development of an artificial oral environment for testing of dental restoratives: Biaxial force and movement control. J Dent Res. 1983;62: 32-36.ArticlePubMedPDF
    • 10. Anderson PJ. Measurement of stress in mastication I. J Dent Res. 1956;35: 664-670.ArticlePubMedPDF
    • 11. Bates JF, Stafford GD, Harrison A. Masticatory function--A review of the literature II. Speed of movement of the mandibule, rate of chewing and forces developed in chewing. J Oral Rehabil. 1975;2: 349-361.PubMed
    • 12. Jemt T, Karlsson S, Hedegard B. Mandibular movement of young adults recorded by intraorally placed light emitting diodes. J Prosthet Dent. 1979;42: 669-673.PubMed
    • 13. Uhlig H. Uber die Kaukraft. Dtsch Zahnarztl Z. 1953;8: 30-45.PubMed
    • 14. Schreiber S. Ein neues Gerät zur Messung und Registrierung von Kaukräfteen. Zahnarztl Rundsch. 1957;66: 127-131.
    • 15. Kraft E. Uber die Bedeuting der Kaukraft für das Kaugeschehen. Zahnarztl Prax. 1962;13: 129-130.
    • 16. Eichner K. Messung der Krafte bei Kauvorgängen. Dtsch Zahnarztl Z. 1963;18: 915-924.
    • 17. Graf H, Grassl H, Aeberhard H-J. A method for measurement of occlusal forces in three directions. Helv Odontol Acta. 1974;35: 7-11.
    • 18. De Boever JA, McCall WD Jr, Holden S, Ash MM. Functional Occlusal force: An investigation by telemetry. J Prosthet Dent. 1978;40: 326-333.PubMed
    • 19. Helkimo E, Ingervall B. Bite force and functional state of the masticatory system in young men. Swed Dent J. 1978;2: 167-175.PubMed
    • 20. Graber , Pfondler . Die Quintessenz einer praxisbezogenen Kronen-und Brückenprothetik. 1980;Berlin: Quintessenz; 25-27.
    • 21. Gibbs CH, Mahan PE, Lundeen HC, Brehnen K, Walsh EK, Holbrook WB. Occlusal force during chewing and swallowing as measured by sound transmission. J Prosthet Dent. 1981;46: 443-449.PubMed
    • 22. Schwickerath H, Coca I. Einzelkronen aus Glaskeramic. Phillip J. 1987;4: 336-338.
    • 23. Krejci I, Lutz F. In vitro Testverfahren zur Evaluation Dentalaler Restaurationssysteme. Korrelation mit In Vivo Resultaten. Schweiz Monatsschr Zahnmed. 1990;100: 1445-1449.PubMed

    Citations

    Citations to this article as recorded by  
    • The effect of intermittent composite curing on marginal adaptation
      Yong-Hwan Yun, Sung-Ho Park
      Journal of Korean Academy of Conservative Dentistry.2007; 32(3): 248.     CrossRef
    CanvasJS.com
    CanvasJS.com
    CanvasJS.com

    • ePub LinkePub Link
    • Cite
      CITE
      export Copy Download
      Close
      Download Citation
      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:
      • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
      • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
      Include:
      • Citation for the content below
      Development of chewing simulator
      J Korean Acad Conserv Dent. 2003;28(1):34-40.   Published online January 31, 2003
      Close
    • XML DownloadXML Download
    Figure
    • 0
    Development of chewing simulator
    Image Image Image Image Image Image Image Image
    Fig. 1 Chewing simulator, front view
    Fig. 2 Chewing simulator, front view of chamber part and position control table
    Fig. 3 Chewing simulator, front view of chamber part
    Fig. 4 Chewing simulator, side view of chamber part
    Fig. 5 Motor part of chewing simulator
    Fig. 6 Movement of CAM
    Fig. 7 Diagram of PWM driver movement
    Fig. 8 Controlling part
    Development of chewing simulator

    Restor Dent Endod : Restorative Dentistry & Endodontics
    Close layer
    TOP Mpgyi